Synthes pelvic inventory. Synthes products supplied in a non-sterile condition must...

DePuy Synthes 2.7 mm variable angle locking calcaneal plating system.

Complete Synthes Modular Hand Inventory Remote Form online with US Legal Print. Easily fill unfashionable PDF blank, modify, and sign them. Save with instantly send your ready documents.of sizes providing surgeons thoracolumbar and pelvic fixation options for adolescent and adult pathologies. Available EXPEDIUM VERSE Screw Sizes Diameter Lengths 4.35mm …Inventory ontrol orm 3 3 Miscellaneous Implants Instruments Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPPROXTIBICF001 07/22 219.98 Washer, 7.0 mm 292.20 2.0 mm K-wire, 150 mm, …Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. Drill Bits, quick couplingPRODUCT CODES. DESCRIPTION. The Orthopaedic Cable System is a cerclage system designed for use with the Cerclage Positioning Pins and Hex Buttons in general orthopaedic trauma surgery, prophylactic banding during total joint procedures, and temporary reduction during open reduction procedures. Product Specifications. How to Use This Device.Synthes Screw Reference Chart Reference Chart Screws, Drill Bits, Taps and Guide Wires. Locking Screws, Guide Wires, Drill Bits and Taps ... SCREW DIAMETER (mm) Thread Diameter 1.0 1.3 1.5 2.0 2.4 2.7 3.5 4.0 4.5 6.5 Cortex, self-tapping Cortex Pelvic Shaft Cortex Cancellous Cortex Shaft Malleolar Cancellous and Non- and Non- and Non-The Synthes Large External Fixation Systems is intended to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: • Stabilization of soft tissues and fractures • Polytrauma/multiple orthopaedic trauma • Vertically stable pelvic fractures, or as a treatment adjunctVeterinary Inventory Controller Contact Large Fragment Screws, Drill Piece, Taps Synthes (USA) To Order: (800) 523-0322 Date: Synthes (Canada) Ltd. To Order: (800) 668-1119 Hospitalization: Account # Implants 4.5. Synthes Low Profile Pelvic Inventory.Case Information: Synthes USA, LLC Synthes (Canada) Ltd. To order: (800) 523-0322 To order: (800) 668-1119. INVENTORY CONTROL FORM 3.5 mm LCP Distal Tibia T-Plate Implants (cont'd) Instruments 4.0 mm Cancellous Bone Screws, fully threaded LENGTH LENGTH 206.010 10 mm 206.012 12 mm3.5 mm Low Profile Pelvic System. Ouch! Your graphics card does not support WebGL. Find out how to fix it here. Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions. visualized by pixelmolkerei.ch. Interactive 3D Web application by pixelmolkerei.Journal of Orthopaedic Trauma, Vol 18(6):361-368 lbid. Synthes TFN - Titanium Trochanteric Fixation Nail System Technique Guide... Page 7 Lag Screw 0.5 (112 lbs) 1000 10,000 100,000 1,000,000 10,000,000 Cycles Test conducted at Legacy Research and Technology Center, Portland, OR. Test conducted at Synthes Mechanical Testing Lab, West ...Inventory Control Form (Titanium) View PDF . Surgical Technique Guide Synthes/Limelight - 3.5 mm LCP® Superior Anterior Clavicle Plates . Select all documents (2)Pelvis Reconstruction Plates 3.5 19 Reconstruction J-Plates 3.5 19 Symphyseal Plates 3.5 19 Femur LCP DHS Plates 20 ... 4 Synthes LCP Locking Compression Plate Ordering Information Basic LCP Plates * no combi-holes 0X6.000.017_AD.qxp:0X6.000.017 02.12.2008 13:39 Uhr Seite 4. Synthes 5The MCMI-IV is an inventory designed to help assess, diagnose, and provide treatment options for individuals with personality disorders. The MCMI-IV provides mental health clinicia...Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°The Variable Angle LCP™ Curved Condylar Plate is a distal femur implant designed to address multiple patient anatomies, fracture patterns and surgical situations including supracondylar, intra-articular and extra-articular condylar fractures, and periprosthetic fractures. Product Specifications. How to Use This Product.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7184-C /09 Inventory Control Form 3.5 mm LCP Extra-articular Distal Humerus Plates (Stainless Steel and Titanium) Available nonsterile or sterile-packed. Add “S” to product number for ...Double/Triple Pelvic Osteotomy Plates Surgical Technique DePuy Synthes 1 Screw Holes The DePuy Synthes Vet DPO/TPO plate is designed with two distinct screw-hole technologies to accommodate all plating modalities. The plate includes three stacked Combi™ holes on the caudal side, and three stackedVariable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures – 3-hole and 6-hole plates are recommended. Simple Fractures – Core, 3-hole, and 6-hole plates may be ...A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.and Pelvic C-Clamp Cannulated Nails. Schanz Screws and Steinmann Pins can be used in various anatomical locations in the body based on the external fixation and distraction system being utilized. The Pelvic C-Clamp Cannulated Nails are only used in the pelvic ring. All external fixator implants are single packed. Schanz screws and Steinmann pinsA-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010synthes.vo.llnwd.netOrthopaedic Foot Instruments Surgical Technique DePuy Synthes 1 MR Information The Orthopaedic Foot Instruments have not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration or image artifact in the MR environment. The safety of the Orthopaedic FootThe TomoFix knee osteotomy system is based on the Locking Compression Plate system (LCP) and enables angular-stable connections between the screw and plate. This angular stability allows the stable fixation of an open-wedge osteotomy and hence its rapid osseous healing. Note: Plan the type and position of the osteotomy.3.5 mm Low Profile Pelvic System. Ouch! Your graphics card does not support WebGL. Find out how to fix it here. Please refer to the instructions for use for a complete list of …Inventory Control Form Titanium MatrixMIDFACE ™ Plating System 0.4 mm Malleable 04.503.081 38 mm x 45 mm 04.503.083 100 mm x 100 mm 04.503.086 Small arc 04.503.087 Large arc 04.503.090 30 mm diameter 04.503.091 70 mm diameter 04.503.092 100 mm diameter Titanium MatrixNEURO Contourable Mesh 03.503.368 Bending Template, 2 x 3Product Codes: 02.118.002, 02.118.002S, 02.118.003... View More. PRODUCT CODES. DESCRIPTION. The 2.7 mm/3.5 mm VA LCP™ Ankle Trauma System is a comprehensive plating system that merges variable angle locking screw technology with conventional plating techniques for fixation of the ankle when growth plates have fused. Product Specifications.DESCRIPTION. Our 2.7/3.5 mm LCP™ Distal Fibula Plates are part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. Available in stainless steel or titanium, these plates are anatomically pre-contoured for the lateral and posterolateral aspects of the distal fibula.Universal Small Fragment System System Catalog DePuy Synthes 12 Instruments Core System Trays Anatomic Implant Trays Case & Lid Options Set Information Instruments (Continued) SKU Description 03.133.175 2.5 mm Hex Driver Shaft, Self-Retaining Length 100 mm with Quick Coupling 03.133.200 Plate Bending Iron Closed for 2.7/3.5 mm PlatesBiodur 108 Alloy allows the Zimmer Cannulated System to feature large cannulation without compromising screw strength. The large cannulation accommodates a large/stiff guide wire. Guide wires are designed to increase strength and stiffness to help minimize skiving, deflecting, or "walking" on the bone. This aims to afford increase accuracy ...2 DePuy Synthes Surgical Technique MatrixMIDFACE™ Plate and Screw System MatrixMIDFACE Plate and Screw System Description The DePuy Synthes MatrixMIDFACE Plate and Screw Sys-tem consists of a variety of plates and meshes that come in multiple shapes and sizes to meet the anatomical needs of the patient. This system is designed for use with theSynthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10175-C 5/11 2.4 mm/2.7 mm VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm VA-LCP Forefoot/Midfoot Plating System 02.211.230 0° right 02.211.231 0° left 02.211.232 5 ...02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.The Acutrak 2 - 7.5 is available in sizes from 40 mm to 120 mm and is inserted using a 4.0 mm hex driver over a .094" guide wire. The Acutrak 2 - 5.5 is part of the latest evolution in fully-threaded headless screw fixation. With instrumentation designed to simplify the surgical technique, the Acutrak 2 - 5.5 is composed of 8 unique screw size ...of sizes providing surgeons thoracolumbar and pelvic fixation options for adolescent and adult pathologies. Available EXPEDIUM VERSE Screw Sizes Diameter Lengths 4.35mm …Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2933-M 12/12 Inventory Control Form 4.5 mm, 6.5 mm, 7.0 mm and 7.3 mm Cannulated Screws 4.5 mm Cannulated Screws, partially threaded LENGTH LENGTH 214.520 20 mm 214.522 22 mm 214.524 24 mm 214. ...Permits rapid reduction and stabilization of the posterior pelvic ring. Description The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp allows rapid reduction ...• DePuy Synthes recommends predrilling in dense bone when using 5 mm or 6 mm screws. Drill speed rate should never exceed 1,800 rpm, particularly in dense, hard bone. Higher drill speed rate can result in thermal necrosis of the bone, soft tissue burns, and an oversized hole to be drilled. The adverse effects of an oversizedof the DePuy Synthes Distal Radius Fixator construct, and it may be necessary to optimize MR imaging parameters, to compensate for the presence of the fixation frame. Representative devices used to assemble a typical DePuy Synthes Distal Radius Fixator have been evaluated in the MRI chamber and worst-case artifact information is provided below.The recently introduced implant FNS (DePuy Synthes, Zuchwil, Switzerland) (Fig. (Fig.1) 1) was developed for the dynamic fixation of FNFs. The FNS includes three parts: an ARScrew, a bolt, and a plate. The plate provides angular stability (a fixed angle between the bolt and the ARScrew).4 Synthes Large and Medium-Size External Fixators Surgical technique The modular construction of Large and Medium-size External Fixators makes them highly flexible. A variety of proven forms of assembly can be used to externally stabilize long, tubular bones and pelvic ring fractures as well as arthrodesis and osteotomies.Position the image intensifier as for an AP view of the proximal femur. Using long forceps, hold the ruler paral-lel to the femur on the lateral side of the upper leg. Position the ruler such that the end is located at or just below the level of the tip of the greater trochanter. Mark the skin on the lateral side.2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.Nail for Pelvic C-Clamp, cannulated, Stainless Steel Article No. Length (mm) 02.306.006 190 02.306.007 210 Steinmann Pin, Stainless Steel Article No. B (mm) Length (mm) 293.000.302150 3.0 293.000.352200 3.5 ... Synthes External Fixation and Distraction Systems consists of various implants including Schanz Screws (self-tapping, self-drilling …The Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant.SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7889-C 2/12 Inventory Control Form Titanium Modular Mini Fragment LCP System 2.0 mm, 2.4 mm and 2.7 mm Instrument and Implant Modules 2.0 mm Titanium Cortex Screws, self-tapping LENGTH LENGTH ...indiquées dans la notice « Informations importantes » de Synthes. Traitement/reconditionnement du dispositif Les instructions de traitement des implants et de reconditionnement des boîtes, plateaux d'instruments et dispositifs réutilisables sont détaillées dans la brochure Synthes « Informations importantes ».2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.Description. The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp al-lows rapid reduc tion and stabilization of these unstable pelvic ring fractures.Inventory Control Form Modular Foot System Implants and Instruments 2.0 mm Cortex Screws, self-tapping Length 201.808 201.810 201.812 201.814 201.816 201.818 201.820 201.822 201.824 3.5 mm Cortex Screws, self-tapping Length 204.810 10 mm 204.812 12 mm 204.814 14 mm 204.816 16 mm 204.818 18 mm 204.820 20 mm 204.822 22 mm 204.824 …Pelvic Implants and Instruments • Surgical Technique 11 Pelvic reduction forceps The pelvic reduction forceps facilitate the ilioinguinal and Kocher-Langenbeck surgical approach. The jaws of all the larger forceps are long enough to accommodate the innominate bone, from the iliac crest to the pelvic brim.The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who hasThe Synthes Low Profile Reconstruction Plates are intended for pelvic and acetabular reconstruction and fixation of fractures of the distal humerus, clavicle, and scapula. Prescription Use X AND/OR Over-The-Counter Use (Per 21 CFR 801.109) (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE -CONTINUE ON …Variable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures - 3-hole and 6-hole plates are recommended. Simple Fractures - Core, 3-hole, and 6-hole plates may be ...20-65mm features which help surgeons to meet the challenge of complex pathologies. 20-65mm EXPEDIUM VERSE Implants are available in an extensive range 20-65mm of sizes providing surgeons thoracolumbar and pelvic fixation 30-100mm options for adolescent and adult pathologies. Page 11 The EXPEDIUM VERSE SYSTEM is presented in four core …Dr. Rahul Vaidya is a paid consultant by Smith and Nephew and Johnson and Johnson/Synthes USA to develop an FDA approved device for the INFIX. The implants depicted are off the shelf implants used in the INFIX method. ... The INFIX procedure for anterior pelvic fixation is based on standard techniques that are familiar to the Orthopaedic Pelvic ...4 DePuy Synthes The Anterior Approach Table-less Surgical Technique. Pre-Operative Set-up . Room Set-up. The OR is set up such that the instruments are on the . operative side or at the foot of the patient. Generally, the use of 2 back tables (A), 2 Mayo stands (B) and 1 basin stand (C) is sufficient.3.5 mm. Remove the cortex screw from hole 1 and replace it with a bicortical, self-tapping locking screw. Screw the drill sleeve exactly into the threaded part of the combi-hole and drill the hole with the LCP drill bit 4.3 mm. Determine the screw length and insert the screw as described on page 15.Inventory Control Form 2.0 mm Quick Insertion Screw (QIS) and 2.0, 2.5, 3.0, 3.5, 4.0 mm Cannulated Compression Headless Screws (CCHS) Implants The screws are made of titanium alloy (TAV) 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 .... J5294-F 10/12 These implants and instruments are available nonSynthes Surgical Pelvic Reduction Forceps 398.88 $ 375.00 and Pelvic C-Clamp Cannulated Nails. Schanz Screws and Steinmann Pins can be used in various anatomical locations in the body based on the external fixation and distraction system being utilized. The Pelvic C-Clamp Cannulated Nails are only used in the pelvic ring. All external fixator implants are single packed. Schanz screws and Steinmann pinsSynthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes "Import-ant ... A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Ca Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 02.112.61504.112.615 Right CS34 DePuy Synthes The Anterior Approach Table-less Surgical Technique. Pre-Operative Set-up . Room Set-up. The OR is set up such that the instruments are on the . operative side or at the foot of the patient. Generally, the use of 2 back tables (A), 2 Mayo stands (B) and 1 basin stand (C) is sufficient. Pelvic Implants and Instruments • Surgical Technique 11 P...

Continue Reading